Important specifications
Max. Pressure
/ b a r /
Noise level
Spray condition Recommended
Measuring point
1m backwards from gun , 1.6 height
HVLP Compliant Spray Gun LOW VOLUME LOW PRESSURE
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following marked items which are especially important.
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property
damage.
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are the minimum
necessary conditions. Follow national and local regulations regarding fire prevention, electricity and safety as well as
your own company regulations.
Main specifications
1. Atomizing air pressure means air pressure at gun inlet when trigger is pulled and air flows
This Anest-iwata spray gun kit complies to ATEX
regulations 94/9/EC,
Protection level
2 G XSuitable for use in Zones 1 and 2.
X marking
Any static electricity discharge from the spray gun
is to be diverted to the grounded the conductive
air hose as stipulated.
LPH-101-L
V
P
INSTRUCTION MANUAL
This manual contains IMPORTANT WARNINGS and INSTRUCTIONS.
Equipment in this manual is exclusively for painting purposes.
Do not use for other purposes.
The operator shall be fully conversant with the requirements stated in this
instruction manual including important warnings, cautions and operation and
correct handling.
Read and understand the instruction manual, before use and retain for
reference.
Max. Temperature
Atmosphere
5℃~40℃
AirFluid
5℃~43℃
Recommended condition
Model
Type of
feed
Nozzle
orifice
Air cap
1 At
omizing
air pressure
MPa (bar /PSI)
Air pressure
inside air cap
MPa (bar/PSI)
Fluid output
Set
Mark
φ mm (in)
ml/min
Air
consumption
l/min (cfm)
Pattern
Width
Mm (in)
Air & fluid
Connection
Mass
g (lbs)
LPH-101 -082LVP
0.8(0.031)
100
230 (9.1)
Air
LV
6
0.18 1.8 /25)
0.05
(0.5 /7.1)
280 (9.9)
Pressure
250(9.8) 1.0(0.039)
150
LPH-101-102LVP
1/4
NPS 1/4
Fluid
3/8
NPS
3/8
295
(0.65)
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - INSTRUCTION MANUAL

- 1 - Important specifications Max. Pressure 0.68MPa / 6.8 b a r / 98

Page 2 - How to connect

Safety precautions Fire and explosion 1. Spark and open flames ar

Page 3 - CAUTION

How to operate Recommended paint viscosity differs according to paint property and p ainting conditions. 12~23 sec/Ford cup#4 is recommendable. Th

Page 4 - Troubleshooting

please order nozzle needle set. - 4 - No. Description Q’ty 8 Air valve 1 9 Air valve spring 1 10 Fluid adj. guide 1 11 Fluid needle spring 1 12